Automatic Back-Flushing Filter
Automatic Back-Fhushing Filter has metal back flushing filter cartridges inside. When filter elements clogged, a specially designedback-flushing anm will clean the elements one by one. When filtering. the water enters the element fiom both ends. When self-cleaning, thetop end partly opens and the water flushed out of the bottom end.
Technical Parameter
Design flow max | 1200m³/h |
Minimum operating pressure | 0.2Mpa |
Maximum working pressure | 0.7Mpa |
Clean filter pressure drop | 0.1Mpa |
Operating temperature | 65℃ |
Filtration precision | 0.025-6μm |
Control Voltage | 24VDC |
Rinse water consumption | (minimum working pressure)0.05T |
Housing material | carbon steel,stainless steel |
Technical Feature
Easy installation, Can install to pipeline directly.
Small volume, lower cost, no filter media,long life time.
High automatic level which is good for operation andmanagement, can be long-term and unmannedmanagement operation.
Small pressure loss, energy saving, the use of mainhydraulic back washing.No need back wash water.
Wide application, It can maintain the normal operationin the process of any periodic back washing.